Product Introduction

CZB5E Series Intelligent Charger is the organic combination of leakage transformer, techn

ology of Silicon-controlled rectifier and Microcomputer Control. This device could optimize Wsa

+Pulse charging characteristic curve. As charge voltage of battery increases, charge current d

ecreases automatically.

Pulse charge would be performed before gas emissions or in late stage of recharge. On the

premise of guarantee adequate battery power, this device would lower greatly internal temperature

and reduce gas emissions of battery, prolong the life of battery effectively and raise the charging

efficiency eventually.

The whole product has simple structure, convenient operation, complete functions and high

efficiency.

2.Applications

This device would be applicable to recharge of lead-acid batteries which could be used in

various electric vehicle such as power pallet trucks, fork-lift truck, lift truck, electronic tour bus.

3.Operating conditions

(1)No higher than 2000 meters in altitude.

(2)Ambient temperature between 10 and 40 degrees C.

(3)Relative humidity not exceed 85% for conditions of ambient temperature around 20ºC ±5ºC.

(4)Store in a place free from conductive dust & the risk of explosion.

(5)Do not store in harmful atmosphere such as corrosive gas, insulating gas, steam.

(6)Store in a place free from rain & snow

(7)Deviation from vertical shall be less than 5 degrees. Working situation without violent vibration

and striking.

Single-phase AC(1NPE) or two-phase AC(2PE) input power

voltage. The code of the E, Frequency:50-60Hz.

 

Specification

Input current     A

Input power        kVA

Output current

    DC A

Battery parameters

Outline dimension mm

Net weight

kg

110V

220V

380V

V

7.5-10h (AH)

   

E24V/20A

 

3.4

 

0.8

20 24 115-160

240×350×260

 21

E24V/25A

 

4.3

 

0.9

25 24 145-200

240×350×260

21

E24V/30A

 

5.1

 

1.1

30 24 175-240

240×350×260

21 

E24V/35A

 

6.0

 

1.3

35 24 205-280

240×350×260

21 

E24V/40A

 

6.8

 

1.5

40 24 230-320

240×350×260

224 

E24V/45A

 

7.7

 

1.7

45 24 260-360

240×350×260

24 

E24V/50A

 

8.5

 

1.9

50 24 290-400  

240×350×260

26 

E24V/55A

  9.4   2.1 55  24  320-440   

240×350×260

26 
E24V/60A  20.5     2.3 60  24  350-480   

280×430×280

34 
E24V/65A  22.2     2.4 60  24  375-520   

280×430×280

34 
E24V/65A    11.1  6.4 2.4 65  24  375-520   

466×360×783

40 
E24V/80A    13.6  7.9 3.0 80 24 465-640  

466×360×783

 40
E36V/30A    7.7   1.7 30  36  175-240  

240×350×260

24 

E36V/35A

   8.9   2.0 35 36  200-280   

240×350×260

25 

E36V/40A

   10.2   2.3 40  48  230-320   

240×350×260

25 

E48V/25A

   8.5   1.9 25  48  145-200   

240×350×260

25 

E48V/30A

   10.2   2.3 30  48 175-240   

240×350×260

28 

E48V/35A

   11.9   2.6 35  48  205-280   

240×350×260

28 

E48V/45A

   15.3  8.9 3.4 45  48  260-360   

466×360×783

42 

E48V/55A

   18.8  10.9 4.1 55  48  320-440   

466×360×783

46 
E48V/65A    22.2  12.8 4.9 65  48  375-520   

466×360×783

50 
E48V/80A    27.3  15.8 6.0 80  48  465-640   

466×360×783

 56
E72V/25A    12.8   2.8 25  72 145-200   

280×430×260

34 
E72V/30A    15.3   3.4 30  72  175-240   

280×430×260

34 

Three-phase AC(3/PE) input power voltage. The code of the D, Frequency: 50/60Hz

 

Specification

Input current     A

Input power        kVA

Output current

    DC A

Battery parameters

Outline dimension mm

Net weight

kg

220V

380V

415V

V

7.5-10h (AH)

D48V/55A

 10.8  6.3  5.7  4.1  55  48 320-440  

466×360×783

  
62

D48V/65A

12.8  7.4  6.8  4.9  65  48  375-520  65 

D48V/80A

15.7  9.1  8.3  6.0  80  48  465-640  68

D48V/100A

19.7  11.4  10.4  7.5  100  48  580-800  526×360×883       86

D48V/120A

23.6  13.7  12.5  9.0  120  48  700-960  95 

D80V/65A

21.3  12.3  11.3  8.1  65  80 375-520  87 

D80V/70A

23  13.3  12.2  8.8  70  80  405-560  87 

D80V/80A

26.2  15.2  13.9  10  80  80  465-640  89 

D80V/100A

 32.8 19  17.4  12.5  100  80  580-800  95 

D80V/120A

39.4 22.8  20.9  15  120  80  700-960  107

D96V/70A

30.4  17.6    11.6  70  96  405-560  680×450×1190       70

D96V/80A

 34.8 20.1     13.2 80 96  465-640 75 

D96V/90A

39.1  22.6    14.9  90  96  520-720  85 

D96V/100A

43.4  25.1    16.6  100  96  580-800  95 

D96V/125A

54.3  31.4    20.7  125  96  725-1000  120 

D96V/150A

65.2  37.7    24.8  150  96  870-1200  145 

D96V/170A

73.8  42.8    28.1  170  96  985-1360  165 

D120V/160A

86.9  50.3    33.1  160  120  930-1280   

680×550×1400

220

D120V/180A

97.7  56.6    37.2  180  120  1045-1440  250

D120V/200A

108  62.9    41.4  200  120  1160-1600   

800×550×1400

245

D120V/220A

119 69.2    45.5  220 120  1275-1760  270 

D312V/20A

 28.8 16.3    10.8  20  312 115-160   

526×360×883

 89

D324V/20A

 29.3 17    11.2  20  324 115-160  89


 

7.png

1)  Startup setting:For selecting the starting mode of the charger, normal startup or delayed  start.

2)   Current indicator lamp:This lamp would indicate charging current magnitude .The brighter this lamp appears,the greater the current . With all lights on, it shows charging current has increased to its maximum value, namely the rated current.

3)   “Information” key:

a. Press “Info.” key for 4 seconds, release the key till the indicator lamp of equalization charge lights up, it indicates that mode of equalization charge has been selected.

b. Press “Info.” key for 10 seconds, release the key till the indicator lamp of initial charge lights up, it indicates that mode of initial charge has been selected.

c. Press “Info.” key for 6 seconds: Charge mode you have selected would be canceled.

(Note: the above setting is only applicable to ordinary lead-acid batteries)

4) Status indicator lamp:

a. Indicator lamp “Working”: When this light is on, it shows this device is charging at the moment.

b. Indicator lamp “80%”: When this light is on, it shows recharge capacity has exceeded 80%.

c. Indicator lamp “100%”: When this light is on, it shows battery been charged completely, which means the battery is full of energy now.

d. Indicator lamp of “Equalization Charge”: When this light is on, it shows mode of equalization charge has been selected this time. When this light flashing, it shows equalization charge is performed at the moment.

e. Indicator lamp of “Initial”: When both this and operation indicator lamp are on, it shows initial charge is performed at the moment.

f.   : When this light is on, it shows there is something wrong with this charger. Equipment fault information could be acquired through the number of current indicator lamps which are on. Each number represents different fault information. For details, please refer to Chapter 7.

Online Consultation

Pre sales support 021-58222666/58228686

Sales Emergency 18918621852

After-sale service 4008883026、
021-58221666/58221622

Technical support 021-58228080、
13918674668

Emergency complaints 13901854050

Contact Us
OTHER PRODUCTS
Other Products